No picture available

Ring Core Chokes: Series B82723 for Power Lines

  • LR from 0.45 to 56 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82724 … B82726
No picture available

Ring Core Chokes: Series B82722 for Power Lines

  • LR from 1.2 to 47 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82723 … B82726
No picture available

Ring Core Chokes: Series B82721 for Power Lines

  • LR from 0.2 to 39 mH
  • Rated voltage: 250 V AC (50/60 Hz)
  • Higher inductance or intermediate values possible upon request
  • Approx. 1% stray inductance for symmetrical interference suppression
  • Higher rated current IR available with series B82722 … B82726
  • Vertical version with lead spacing 5 x 10 mm available (B82721J*)

No picture available

D Core Chokes: Series B82731M for Power Lines

  • LR from 3.3 to 100 mH
  • Nominal voltage 250 V AC/250 V DC
  • Creepage distances and clearances > 3 mm
  • Height: 20 +0.5 mm;
    Lead spacing: 12.5 x 10 ±0.2 mm
  • Higher inductance or intermediate values possible
  • Horizontal series B82731H with height 15.5 mm max. available
  • Higher rated current IR available with series B82732R/W (IR up to 2.2 A) and
    B82734R/W (IR up to 4.6 A)
No picture available

E Core Chokes: Series B82731-T for Power Lines

  • LR from 3.3 to 100 mH
  • Nominal voltage: 250 V AC/ 250 V DC
  • Creepage distances and clearances: > 3 mm
  • Height: 21.1 mm max;
    Lead spacing: 10 x 10 ±0.2 mm
  • Higher inductance or intermediate values possible
  • Approx. 2% stray inductance for symmetrical interference suppression
No picture available

Frame Core Chokes: Series B82732F*B001
for Power Lines

  • LR from 10 to 100 mH
  • Rated voltage: 250 V AC
  • Clearance and creepage distances: > 3 mm
  • Lead spacing: 18.75 x 10.0 ±0.2 mm
  • Climatic category 40/125/56 (to IEC 60068-1)
  • Excellent differential-mode suppression
No picture available

Frame Core Chokes: Series B82733F*B001
for Power Lines

  • LR from 10 to 100 mH
  • Rated voltage: 250 V AC
  • Clearance and creepage distances: > 3 mm
  • Lead spacing: 22.5 x 20.0 ±0.2 mm
  • Climatic category 40/125/56 (to IEC 60068-1)
  • Excellent differential-mode suppression
 

Effective February 1, 2015, www.epcos.com changed to www.tdk.eu. You will be redirected automatically, but you are kindly asked to refresh your bookmarks.
Web services cover information for EPCOS and TDK brand products as well as company information for EPCOS and TDK Europe.